S60M* TO-5Silicon Based Thermopile DetectorFeatures:A single-channel silicon-based thermopile with very high output for its small 0.6mm x 0.6mm active area in a TO-5 package. Delivers a very fast 12ms time constant in Argon encapsulation gas and even faster with Neon gas at 9ms.Delivers a very low Temperature Coefficient of Responsivity of -0.04%/°C. Applications:Excellent for non-contact temperature and gas analysis. Benefit: High output, small active area, fast time constant that has a higher cost. Options:
Datasheet: For more detailed information see the datasheet (PDF). |
S60M Detector circuit overlay
S60M TO-5 Thermopile Detector |
S60M TO-5 Thermopile Detector Technical Specifications
Specifications apply at 23°C with KBr Window and Argon encapsulating gas
Parameter |
Min |
Typical |
Max |
Symbol |
Units |
Comments |
|
Active Area size |
.6 x .6 |
AA |
mm |
Hot junction size, per element. |
||
|
Element Area |
.36 |
A |
mm2 |
|||
|
Number of Junctions |
72 |
|
|
Per element. |
||
|
Number of Channels |
1 |
|
|
Per detector package. |
||
|
Output Voltage |
90 |
120 |
140 |
Vs |
μV |
DC, H=330μW/cm2 (3) |
|
Signal-to-Noise Ratio |
2,123 |
3,125 |
4,294 |
SNR |
√Hz |
DC, SNR=Vs/Vn |
|
Responsivity |
75.8 |
101.0 |
117.8 |
|
V/W |
DC, |
|
Resistance |
65 |
90 |
110 |
R |
kΩ |
Detector element |
|
Temperature Coefficient of |
|
-.04 |
|
|
%/°C |
Best linear fit, 0° to 85°C (1) |
|
Temperature Coefficient of R |
|
.11 |
|
|
%/°C |
Best fit, 0° to 85°C (1) |
|
Noise Voltage |
32.6 |
38.4 |
42.4 |
Vn |
nV/√Hz |
Vn2=4kTR |
|
Noise Equivalent Power |
.28 |
.38 |
.56 |
NEP |
nW/√Hz |
DC, NEP= VnHA/Vs (2) |
|
Detectivity |
1.1 |
1.6 |
2.2 |
D* |
108√Hz/W |
DC, D*=Vs/ VnH√A (2) |
|
Time Constant |
|
12 |
|
Τ |
ms |
Chopped, -3dB point (1) |
|
Field of View |
64°/81° |
FOV |
Degrees |
See Assembly Drawings for FOV Description. |
||
|
Package Type |
TO-5 |
Standard package hole size:Ø.080 |
||||
|
Operating Temperature |
-50 |
|
100 |
Ta |
°C |
|
|
General Specifications: Notes:
* Protected by U.S. Patent No. 5, 059,543 and U.S. Patent No. 5,100,479 |
||||||