+1 (734) 426-3921
Questions about Dexter detectors? Call today. Outside the U.S., contact the representative nearest you.

DR34 Compensated

DR34 Compensated Detector circuit overlay
DR34 Compensated Detector circuit overlay
DR34 Compensated Thermopile
DR34 Compensated Thermopile

Thin Film Based Thermopile Detector

Features:
A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity.
Applications:
Industrial and medical monitoring including infant incubators.
Benefit:
Compensated rectangular shaped active area in a TO-5 package with moderate output.
Options:
  1. See Standard Windows and Filters (PDF) for list of optical filter options.
  2. See Thermopile Configuration Table for more options.
Datasheet:
For more detailed information see the datasheet

DR34 Thermopile Detector Technical Specifications

Specifications apply at 23°C with KBr Window and Argon encapsulating gas

Parameter
Min
Typical
Max
Symbol
Units
Comments

Active Area size

3.16 x .4

AA

mm

Hot junction size, per element.

Element Area

1.264

A

mm2

 

Number of Junctions

40

 

 

Per element.

Number of Channels

1 Compensated

 

 

Per detector package.

Output Voltage

90

115

130

Vs

μV

DC,  H=330μW/cm2 (3)

Signal-to-Noise Ratio

4,545

7,099

11,404

SNR

√Hz

DC, SNR=Vs/Vn

Responsivity

21.6

27.6

31.2

V/W

DC, =Vs/HA  (2)

Resistance

8

16

24

R

Detector element

Temperature Coefficient of

 

-.36

 

 

%/°C

Best linear fit, 0° to 85°C (1)

Temperature Coefficient of  R

 

-.2

 

 

%/°C

Best fit, 0° to 85°C (1)

Noise Voltage

11.4

16.2

19.8

Vn

nV/√Hz

Vn2=4kTR

Noise Equivalent Power

.37

.59

.92

NEP

nW/√Hz

DC,  NEP= VnHA/Vs (2)

Detectivity

1.2

1.9

3.1

D*

108√Hz/W

DC,  D*=Vs/ VnH√A  (2)

Time Constant

 

38

 

Τ

ms

Chopped, -3dB point (1)

Field of View

NA

FOV

Degrees

See Assembly Drawings for FOV Description.

Package Type

TO-5 with 3 Pins

   

Standard package hole size:Ø.180"

Operating Temperature

-50

 

100

Ta

°C

 

General Specifications: 
Flat spectral response from 100nm to > 100µm.  Linear signal output from 10-6 to 0.1W/cm2
Maximum incident radiance 0.1W/cm2 , damage threshold ≥ .5W/cm2

Notes:      
(1) Parameter is not 100% tested. 90% of all units meet these specifications.
(2) A is detector area in cm2.
(3)Test Conditions: 500K Blackbody source; Detector active surface 10cm from 0.6513cm Diameter Blackbody Aperture.