+1 (734) 426-3921
Questions about Dexter detectors? Call today. Outside the U.S., contact the representative nearest you.

DR46 Compensated

DR46 Compensated Detector
DR46 Compensated Detector

Thin Film Based Thermopile Detector

Features:
A one-channel compensated thin-film thermopile in a TO-8 package. The active area and compensating element area are 4mm x 0.6mm each. Offers high output with very good signal-to-noise ratio. Internal aperture minimizes channel-to-channel crosstalk increasing sensitivity.
Applications:
Non-contact temperature measurement, fire detection / suppression.
Benefit:
High output, low noise compensated rectangular shaped active area in a TO-8 package.
Options:
  1. See Standard Windows and Filters (PDF) for list of optical filter options.
  2. See Thermopile Configuration Table for more options.
Datasheet:
For more detailed information see the datasheet

Specifications apply at 23°C with KBr Window and Argon encapsulating gas.

Parameter
Min
Typical
Max
Symbol
Units
Comments

Active Area size

4 x .6

AA

mm

Hot junction size, per element.

Element Area

2.4

A

mm2

 

Number of Junctions

50

 

 

Per element.

Number of Channels

1 Compensated

 

 

Per detector package.

Output Voltage

170

210

250

Vs

μV

DC,  H=330μW/cm2 (3)

Signal-to-Noise Ratio

7,692

11,602

16,556

SNR

√Hz

DC, SNR=Vs/Vn

Responsivity

21.5

26.5

31.6

V/W

DC, =Vs/HA  (2)

Resistance

14

20

30

R

Detector element

Temperature Coefficient of

 

-.36

 

 

%/°C

Best linear fit, 0° to 85°C (1)

Temperature Coefficient of  R

 

-.2

 

 

%/°C

Best fit, 0° to 85°C (1)

Noise Voltage

15.1

18.1

22.1

Vn

nV/√Hz

Vn2=4kTR

Noise Equivalent Power

..48

.68

1.03

NEP

nW/√Hz

DC,  NEP= VnHA/Vs (2)

Detectivity

1.5

2.3

3.2

D*

108√Hz/W

DC,  D*=Vs/ VnH√A  (2)

Time Constant

 

40

 

Τ

ms

Chopped, -3dB point (1)

Field of View

N/A

FOV

Degrees

See Assembly Drawings for FOV Description.

Package Type

TO-8 with 3 Pins

   

Standard package hole size:Ø.437

Element Matching

 

5

10

M

%

M=|VA-VB|/VB (2)

Element Separation

 

NA

 

 

mm

Center to Center

Operating Temperature

-50

 

100

Ta

°C

 

General Specifications: 
Flat spectral response from 100nm to > 100µm.  Linear signal output from 10-6 to 0.1W/cm2
Maximum incident radiance 0.1W/cm2 , damage threshold ≥ .5W/cm2
Notes:      
(1)
Parameter is not 100% tested. 90% of all units meet these specifications.
(2)
A is detector area in cm2.
(3)