+1 (734) 426-3921
Questions about Dexter detectors? Call today. Outside the U.S., contact the representative nearest you.

S60M TO-5

S60M Detector circuit overlay
S60M Detector circuit overlay
S60M TO-5 Thermopile Detector
S60M TO-5 Thermopile Detector

Silicon Based Thermopile Detector

Features:
A single-channel silicon-based thermopile with very high output for its small 0.6mm x 0.6mm active area in a TO-5 package. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/°C.
Applications:
High output, small active area, fast time constant that has a higher cost.
Benefit:
Excellent for non-contact temperature and gas analysis.
Options:
  1. See Standard Windows and Filters (PDF) for list of optical filter options.
  2. Internal aperture precisely defines active area for applications with FOV and/or spot size requirements. See Aperture Options (PDF) for available sizes.
  3. See Thermopile Configuration Table for more options.
Datasheet:
For more detailed information see the datasheet

Specifications apply at 23°C with KBr Window and Argon encapsulating gas.

Parameter
Min
Typical
Max
Symbol
Units
Comments

Active Area size

.6 x .6

AA

mm

Hot junction size, per element.

Element Area

.36

A

mm2

 

Number of Junctions

72

 

 

Per element.

Number of Channels

1

 

 

Per detector package.

Output Voltage

90

120

140

Vs

μV

DC,  H=330μW/cm2 (3)

Signal-to-Noise Ratio

2,123

3,125

4,294

SNR

√Hz

DC, SNR=Vs/Vn

Responsivity

75.8

101.0

117.8

V/W

DC, =Vs/HA  (2)

Resistance

65

90

120

R

Detector element

Temperature Coefficient of

 

-.04

 

 

%/°C

Best linear fit, 0° to 85°C (1)

Temperature Coefficient of  R

 

.11

 

 

%/°C

Best fit, 0° to 85°C (1)

Noise Voltage

32.6

38.4

42.4

Vn

nV/√Hz

Vn2=4kTR

Noise Equivalent Power

.28

.38

.56

NEP

nW/√Hz

DC,  NEP= VnHA/Vs (2)

Detectivity

1.1

1.6

2.2

D*

108√Hz/W

DC,  D*=Vs/ VnH√A  (2)

Time Constant

 

27

 

Τ

ms

Chopped, -3dB point (1)

Field of View

64°/81°

FOV

Degrees

See Assembly Drawings for FOV Description.

Package Type

TO-5

   

Standard package hole size:Ø.150"

Operating Temperature

-50

 

100

Ta

°C

 

General Specifications: 
Flat spectral response from 100nm to > 100µm.  Linear signal output from 10-6 to 0.1W/cm2
Maximum incident radiance 0.1W/cm2 , damage threshold ≥ .5W/cm2

Notes:      
(1) Parameter is not 100% tested. 90% of all units meet these specifications.
(2) A is detector area in cm2.
(3)Test Conditions: 500K Blackbody source; Detector active surface 10cm from 0.6513cm Diameter Blackbody Aperture.

 

* Protected by U.S. Patent No. 5, 059,543 and U.S. Patent No. 5,100,479